COMPL C4d RUO
Assay Description
1 hour incubation (37°C) + 30 min. (RT) + 30 min. (RT) = 2 hours total incubation time
Catalog number
COMPL C4d RUO
configuration
96 Determinations, 12x8 removable strips
controls
1 low control (ready to use) and 1 high control, ready to use
design
Enzyme immunoassay (ELISA) technique
FDA Status
For research use only, not for use in diagnostic procedures
MSDS
Please inquire
notes
The protocol for this product (see above) is intended to serve as an example only. Please refer to the Instructions For Use provided with the assay kit for precise details.
Sample types
Plasma
Sample volume
10 µL
standards
6 calibrators, ready to use
Standard range
0 / 5 - 400 ng/mL
storage
2 - 8 °C
Species
Human
COMPL TCC RUO
Assay Description
1 hour incubation (37°C) + 30 min. (RT) + 30 min. (RT) = 2 hours total incubation time
Catalog number
COMPL TCC RUO
configuration
96 Determinations, 12x8 removable strips
controls
1 low control (ready to use) and 1 high control, ready to use
design
Enzyme immunoassay (ELISA) technique
FDA Status
For research use only, not for use in diagnostic procedures
MSDS
Please inquire
notes
The protocol for this product (see above) is intended to serve as an example only. Please refer to the Instructions For Use provided with the assay kit for precise details.
Sample types
Plasma
Sample volume
30 µL
standards
6 calibrators, ready to use
Standard range
0 / 10 - 400 ng/mL
storage
2 - 8 °C
Species
Human
27742
Assay Description
1 hour incubation (37°C) + 30 min (37°C) + 30 min. (RT) = 2 hours total incubation time
Catalog number
27742
configuration
96 Determinations, 12x8 removable strips
controls
None provided
design
Enzyme immunoassay (ELISA) technique
FDA Status
For research use only, not for use in diagnostic procedures
notes
The protocol for this product (see above) is intended to serve as an example only. Please refer to the Instructions For Use provided with the assay kit for precise details.
Sample types
Serum, EDTA plasma, and urine
Sample volume
100 µL of properly diluted unknown / determination
standards
7 standards, serially diluted from 1 prepared lyophilized standard
Standard range
0.28 - 18 ng/mL
storage
2 - 8 °C
sensitivity
0.093 ng/mL
Species
Human
27708
Assay Description
Overnight (2 - 8°C) + 2 hours (2 - 8°C) + 20 min. (RT) = Overnight + 2 hours, 20 min. total incubation time
Catalog number
27708
configuration
96 Determinations, 12x8 removable strips
controls
None provided
design
Chemiluminescent immunoassay (LUM) technique
FDA Status
For research use only, not for use in diagnostic procedures
notes
The protocol for this product (see above) is intended to serve as an example only. Please refer to the Instructions For Use provided with the assay kit for precise details.
Sample types
Mouse Serum, EDTA-plasma and Heparin-Plasma. Rat Serum, EDTA-plasma and Heparin-Plasma
Sample volume
10 µL
standards
6 standards
Standard range
9 - 6,480 pg/mL
storage
2 - 8 °C
Species